Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.927
Filtrar
1.
Mikrochim Acta ; 191(5): 264, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622377

RESUMO

Silver nanoparticles supported on metal-organic framework (ZIF-67)-derived Co3O4 nanostructures (Ag NPs/Co3O4) were synthesized via a facile in situ reduction strategy. The resulting materials exhibited pH-switchable peroxidase/catalase-like catalytic activity. Ag NP doping greatly enhanced the catalytic activity of Ag NPs/Co3O4 towards 3,3',5,5'-tetramethylbenzidine (TMB) oxidation and H2O2 decomposition which were 59 times (A652 of oxTMB) and 3 times (A240 of H2O2) higher than that of ZIF-67, respectively. Excitingly, thiophanate-methyl (TM) further enhanced the peroxidase-like activity of Ag NPs/Co3O4 nanozyme due to the formation of Ag(I) species in TM-Ag NPs/Co3O4 and generation of more radicals resulting from strong interaction between Ag NPs and TM. The TM-Ag NPs/Co3O4 nanozyme exhibited lower Km and higher Vmax values towards H2O2 when compared with Ag NPs/Co3O4 nanozyme. A simple, bioelement-free colorimetric TM detection method based on Ag NPs/Co3O4 nanozyme via analyte-enhanced sensing strategy was successfully established with high sensitivity and selectivity. Our study demonstrated that hybrid noble metal NPs/MOF-based nanozyme can be a class of promising artificial nanozyme in environmental and food safety applications.


Assuntos
Cobalto , Nanopartículas Metálicas , Óxidos , Tiofanato , Nanopartículas Metálicas/química , Colorimetria/métodos , Peróxido de Hidrogênio/química , Prata/química , Peroxidases
2.
Biosens Bioelectron ; 255: 116271, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583355

RESUMO

The metal-organic frameworks (MOFs) nanozyme-mediated paper-based analytical devices (PADs) have shown great potential in portable visual determination of phenolic compounds in the environment. However, most MOF nanozymes suffer from poor dispersibility and block-like structure, which often prompts deposition and results in diminished enzymatic activity, severely hindering their environmental applications. Here, we proposed colorimetric PADs for the visual detection of dichlorophen (Dcp) based on its significant inhibitory effect on the two-dimensional (2D) MOF nanozyme activity. Specifically, we synthesized a 2D Cu TCPP (Fe) (defined as 2D-CTF) MOF nanozyme exhibiting excellent dispersibility and remarkable peroxidase-like (POD-like) activity, which could catalyze the oxidation and subsequent color change of 3,3',5,5'-tetramethylbenzidine even under neutral conditions. Notably, the POD-like activity of 2D-CTF demonstrated a unique response to Dcp because of the occupation of Fe-N4 active sites on the 2D-CTF. This property enables the use of 2D-CTF as a highly efficient catalyst to develop colorimetric PADs for naked-eye and portable detection of Dcp. We believe that the proposed colorimetric PADs offer an efficient method for Dcp assay and open fresh avenues for the advancement of colorimetric sensors for analyzing of phenolic toxic substances in real samples.


Assuntos
Técnicas Biossensoriais , Diclorofeno , Estruturas Metalorgânicas , Estruturas Metalorgânicas/química , Técnicas Biossensoriais/métodos , Peroxidases/química , Peroxidase , Colorimetria/métodos , Fenóis , Peróxido de Hidrogênio/química
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 314: 124204, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38569391

RESUMO

The rapid and accurate detection of drug molecules in pharmaceutical formulations and biological samples is of paramount importance. In this research article, we present a novel colorimetric sensor based on carbon dots decorated silver nanoparticles (CDs/AgNPs) for the rapid detection of ketotifen (KTF), a widely used antihistamine drug. The CDs were synthesized via a facile one-step microwave-assisted method and subsequently conjugated onto AgNPs through a simple adsorption process, forming a stable CDs/AgNPs composite. The resulting composite exhibited unique optical properties, including a strong absorption peak at 410 nm with remarkable intensity reduction and color changes upon the addition of KTF. The developed colorimetric sensor exhibited a wide linear range of 3.0-40.0 µg mL-1 (R2 = 0.9996), with a %RSD of 2.41, and a low limit of detection (LOD) of 0.981 µg mL-1. Furthermore, the sensor's practical applicability was evaluated by successfully detecting KTF in eye drops and artificial aqueous humor, demonstrating a remarkable percentage recovery exceeding 96.0 %. Finally, a comprehensive evaluation of the greenness and blueness of the method was performed using analytical eco-scale, GAPI, AGREEprep, and BAGI tools. The results of these assessments indicate its exceptional sustainability. Overall, the proposed method holds significant potential for applications in pharmaceutical quality control and therapeutic monitoring, contributing to improved patient care and drug safety in the field of ophthalmology.


Assuntos
Nanopartículas Metálicas , Humanos , Prata , Cetotifeno , Colorimetria/métodos , Carbono , Soluções Oftálmicas , Humor Aquoso
4.
Anal Methods ; 16(15): 2340-2348, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38562104

RESUMO

The presence of paraquat in the environment poses a danger to human health, leading to a growing demand for an uncomplicated and highly responsive method to detect paraquat. This work reports a new, simple, and sensitive colorimetric aptasensor based on the designed aptamers containing 1-5 paraquat binding sites (R1-R5) in combination with gold nanoparticles (AuNPs). Although the aptamers with more binding sites exhibited greater paraquat interaction capability, the aptasensor based on the R3 aptamer showed the highest detection sensitivity for paraquat in a linear range of 5-50 nM with a limit of detection of 1.29 nM, meaning that it is 2.14 fold more sensitive than the R1-aptasensor. This R3-aptasensor selectively detected paraquat but not the other tested herbicides, including difenzoquat, 2,4-D, ametryn, atrazine, and glufosinate. Also, it efficiently detected paraquat spiked in water samples within the precision acceptance criterion of recovery rates (96.8-105.0%) and the relative standard deviations (1.50-3.81%). These results demonstrated the development of a new aptasensor for paraquat detection, in which the multiple paraquat binding sites of the aptamers could enhance detection sensitivity.


Assuntos
Aptâmeros de Nucleotídeos , Nanopartículas Metálicas , Humanos , Ouro/química , Paraquat , Nanopartículas Metálicas/química , Aptâmeros de Nucleotídeos/química , Colorimetria/métodos
5.
ACS Appl Mater Interfaces ; 16(15): 19359-19368, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38568140

RESUMO

Wearable sensors utilize changes in color as a response to physiological stimuli, making them easily recognizable by the naked eye. These colorimetric wearable sensors offer benefits such as easy readability, rapid responsiveness, cost-effectiveness, and straightforward manufacturing techniques. However, their applications in detecting volatile organic compounds (VOCs) in situ have been limited due to the low concentration of complex VOCs and complicated external interferences. Aiming to address these challenges, we introduced readable and wearable colorimetric sensing arrays with a microchannel structure and highly gas-sensitive materials for in situ detection of complex VOCs. The highly gas-sensitive materials were designed by loading gas-sensitive dyes into the porous metal-organic frameworks and further depositing the composites on the electrospun nanofiber membrane. The colorimetric sensor arrays were fabricated using various gas-sensitive composites, including eight dye/MOF composites that respond to various VOCs and two Pd2+/dye/MOF composites that respond to ethylene. This enables the specific recognition of multiple characteristic VOCs. A microfluidic channel made of polydimethylsiloxane (PDMS) was integrated with different colorimetric elements to create a wearable sensor array. It was attached to the surface of fruits to collect and monitor VOCs using the DenseNet classification method. As a proof of concept, we demonstrated the feasibility of the wearable sensing system in monitoring the ripening process of fruits by continuously measuring the VOC emissions from the skin of the fruit.


Assuntos
Compostos Orgânicos Voláteis , Dispositivos Eletrônicos Vestíveis , Colorimetria/métodos , Compreensão , Pele , Corantes
6.
Anal Methods ; 16(15): 2378-2385, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38572618

RESUMO

Using silver nitrate as the silver source and sodium borohydride as the reducing agent, we synthesized negatively charged silver nanoparticles (AgNPs). Subsequently, the AgNPs solution was mixed with positively charged lead ions, resulting in AgNPs aggregation via electrostatic interactions. This led to a color change in the solution from yellow to purple and eventually to blue-green. Our study focused on a colorimetric method that exhibited high selectivity and sensitivity in detecting cysteine using AgNPs-Pb2+ as a sensing probe. Upon the introduction of cysteine to the AgNPs-Pb2+ system, the absorbance of AgNPs increased at 396 nm and decreased at 520 nm. The formation of a complex between cysteine and lead ions prevented the aggregation of silver nanoparticles, enabling the colorimetric detection of cysteine. The relationship between the concentration of ΔA396/A520 and cysteine showed linearity within the range of 0.01 to 0.1 µM; the regression equation of the calibration curve is ΔA396/A520 = 9.0005c - 0.0557 (c: µM), with an R2 value of 0.9997. The detection limit was found to be 3.8 nM (S/N = 3). This method demonstrated exceptional selectivity and sensitivity for cysteine and was effectively used for the determination of cysteine in urine. Our findings offer a new perspective for the future advancement of anti-aggregation silver nanocolorimetry.


Assuntos
Colorimetria , Nanopartículas Metálicas , Colorimetria/métodos , Cisteína , Chumbo , Prata , Íons
7.
Mikrochim Acta ; 191(5): 244, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578321

RESUMO

The sensing sensitivity was improved for silver nanoparticles (AgNPs)-based colorimetric biosensors by using the most suitable salt to induce AgNPs aggregation. As for the salt composed of low-affinity anion and monovalent cation, the cation-dependent charge screening effect was the driving force for AgNPs aggregation. Apart from the charge screening effect, both the bridging of multivalent cation to the surface ligand of AgNP and the interaction between anion and Ag contributed to inducing AgNPs aggregation. Considering the higher aggregation efficiency of AgNPs resulted in a narrower sensing range, salt composed of low-affinity anion and monovalent cation was recommended for AgNPs-based colorimetric analysis, which was confirmed by fourfold higher sensitivity of DNA-21 detection using NaF than NaCl. This work inspires further thinking on improving the sensing performance of metal nanomaterials-based sensors from the point of colloidal surface science.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Cloreto de Sódio , Prata , Colorimetria/métodos , Ânions , Cátions Monovalentes
8.
Luminescence ; 39(3): e4713, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38515291

RESUMO

As large numbers of people are suffering from gout, an accurate, rapid, and sensitive method for the detection of gout biomarker, uric acid, is important for its effective control, diagnosis, and therapy. Although colorimetric detection methods based on uricase have been considered, they still have limitations as they produce toxic H2O2 and are expensive and not stable. Here, a novel uricase-free colorimetric method was developed for the sensitive and selective detection of uric acid based on the light-induced oxidase-mimicking activity of a new photosensitized covalent organic framework (COF) (2,4,6-trimethylpyridine-3,5-dicarbonitrile-4-[2-(4-formylphenyl)ethynyl]benzaldehyde COF [DCTP-EDA COF]). DCTP-EDA COF has a strong ability to harvest visible light, and it could catalyze the oxidation of 1,4-dioxane, 3,3',5,5'-tetramethylbenzidine under visible light irradiation to produce obvious color changes. With the addition of uric acid, however, the significant inhibition of the oxidase-mimicking activity of DCTP-EDA COF remarkably faded the color, and thus uric acid could be colorimetrically detected in the range of 2.0-150 µM with a limit of detection of 0.62 µM (3σ/K). Moreover, the present colorimetric method exhibited high selectivity; uric acid level in serum samples was successfully determined, and the recoveries ranged from 96.5% to 105.64%, suggesting the high accuracy of the present colorimetric method, which demonstrates great promise in clinical analysis.


Assuntos
Gota , Estruturas Metalorgânicas , Humanos , Oxirredutases , Ácido Úrico , Peróxido de Hidrogênio , Colorimetria/métodos , Urato Oxidase
9.
Analyst ; 149(8): 2223-2226, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38506234

RESUMO

Nanozymes have been widely used as enzyme substitutes. Based on a comprehensive literature survey of 261 publications, we report the significant differences in the Michaelis-Menten constants (Km) between peroxidase-mimicking nanozymes and horseradish peroxidase (HRP). Further, these differences were not considered in more than 60% of the publications for analytical developments. As a result, nanozymes' catalytic activity is limited, resulting in a potentially higher limit of detection (LOD). We used a peroxidase-mimicking Au@Pt nanozyme, which has Km for TMB comparable with HRP and three orders of magnitude higher Km for H2O2. Using the Au@Pt nanozyme as a label for immunoassays, non-optimized nanozyme substrate concentrations led to 30 times higher LOD compared to optimized conditions. The results confirm the necessity of measuring nanozymes' kinetic parameters and the corresponding adjustment of substrate concentrations for highly sensitive detection.


Assuntos
Peróxido de Hidrogênio , Peroxidases , Peróxido de Hidrogênio/química , Catálise , Peroxidase/química , Peroxidase do Rábano Silvestre/química , Colorimetria/métodos
10.
Anal Chim Acta ; 1301: 342471, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38553126

RESUMO

BACKGROUND: ß-Glucuronidase (GUS) is considered as a promising biomarker for primary cancer. Thus, the reliable detection of GUS has great practical significance in the discovery and diagnosis of cancer. Compared with traditional organic probes, silicon nanoparticles (Si NPs) have emerged as robust optical nanomaterials due to their facile preparation, superior photobleaching resistance and excellent biocompatibility. However, most nanomaterials-based methods only output a single signal which is easily influenced by external factors in complex systems. Hence, developing nanomaterial-based multi-signal optical assays for highly sensitive GUS determination is still urgently desired. RESULTS: In this study, we developed a simple and efficient one-step method for the in situ preparation of yellow color and yellow-green fluorescent Si NPs. This was achieved by combining 3-[2-(2-aminoethylamino) ethylamino] propyl-trimethoxysilane with p-aminophenol (AP) in an aqueous solution. The obtained Si NPs showed yellow-green fluorescence at 535 nm when excited at 380 nm, while also exhibiting an absorption peak at a wavelength of 490 nm. Taking inspiration from the easy synthesis step regulated by AP, which is generated through the hydrolysis of 4-aminophenyl ß-D-glucuronide catalyzed by GUS, we constructed a direct fluorometric and colorimetric dual-mode method to measure GUS activity. The developed fluorometric and colorimetric sensing platform showed high sensitivity and accuracy with detection limits for GUS determination as low as 0.0093 and 0.081 U/L, respectively. SIGNIFICANCE: This study provides a facile dual-mode fluorometric and colorimetric approach for determination of GUS activity based on novel Si NPs for the first time. This designed sensing approach was successfully employed for the quantification of GUS in human serum samples and screening of GUS inhibitors, indicating the feasibility and potential applications in clinical cancer diagnosis and anti-cancer drug discovery.


Assuntos
Nanopartículas , Silício , Humanos , Glucuronidase , Colorimetria/métodos , Fluorometria
11.
Biosens Bioelectron ; 254: 116201, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38507928

RESUMO

Developing highly sensitive and selective methods that incorporate specific recognition elements is crucial for detecting small molecules because of the limited availability of small molecule antibodies and the challenges in obtaining sensitive signals. In this study, a generalizable photoelectrochemical-colorimetric dual-mode sensing platform was constructed based on the synergistic effects of a molecularly imprinted polymer (MIP)-aptamer sandwich structure and nanoenzymes. The MIP functionalized peroxidase-like Fe3O4 (Fe3O4@MIPs) and alkaline phosphatase mimic Zr-MOF labeled aptamer (Zr-mof@Apt) were used as the recognition elements. By selectively accumulating dibutyl phthalate (DBP), a small molecule target model, on Fe3O4@MIPs, the formation of Zr-MOF@Apt-DBP- Fe3O4@MIPs sandwich structure was triggered. Fe3O4@MIPs oxidized TMB to form blue-colored oxTMB. However, upon selective accumulation of DBP, the catalytic activity of Fe3O4@MIPs was inhibited, resulting in a lighter color that was detectable by the colorimetric method. Additionally, Zr-mof@Apt effectively catalyzed the hydrolysis of L-Ascorbic acid 2-phosphate sesquimagnesium salt hydrate (AAPS), generating ascorbic acid (AA) that could neutralize the photogenerated holes to decrease the photocurrent signals for PEC sensing and reduce oxTMB for colorimetric testing. The dual-mode platform showed strong linearity for different concentrations of DBP from 1.0 pM to 10 µM (PEC) and 0.1 nM to 0.5 µM (colorimetry). The detection limits were 0.263 nM (PEC) and 30.1 nM (colorimetry) (S/N = 3), respectively. The integration of dual-signal measurement mode and sandwich recognition strategy provided a sensitive and accurate platform for the detection of small molecules.


Assuntos
Técnicas Biossensoriais , Polímeros Molecularmente Impressos , Colorimetria/métodos , Peroxidase/química , Peroxidases
12.
Biosens Bioelectron ; 253: 116143, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452567

RESUMO

A modern agriculture uses alternative pest control methods to boost productivity, leading to an accumulation of organophosphorus (OPPs) congeners. This necessitates an intuitive and quick way to identify OPPs congeners. A colorimetric sensor for detecting OPPs congeners using a double-enzyme cascade reaction has been successfully designed and constructed in this study. The OPPs regulate the color changes induced by manganese dioxide nanoflowers (MnO2 NFs) and specific alkaline phosphatases (ALP) during the etching of gold nanopyramids (Au NBPs). The ascorbic acid (AA) produced by ALP hydrolysis inhibits Au NBPs etching by MnO2 NFs oxidized 3, 3', 5, 5'-tetramethylbenzidine (TMB). By inhibiting ALP catalytic activity, OPPs prevent AA formation. In this process, Au NBPs will undergo further etching, resulting in various colors so they can be analyzed semi-quantitatively with the naked eye. It has been found that different types of OPPs inhibit enzymes differently and therefore result in varying degrees of etching of Au NBPs. Principal Component Analysis (PCA) is performed by smart devices that convert R, G, and B signals into digital signals. This colorimetric array tests various foods (tea, apple, and cabbage). Colorimetric visualization sensors combined with data analysis will be used in real-life product development.


Assuntos
Técnicas Biossensoriais , Praguicidas , Praguicidas/toxicidade , Praguicidas/análise , Óxidos , Compostos Organofosforados , Compostos de Manganês , Colorimetria/métodos , Ácido Ascórbico , Fosfatase Alcalina
13.
Anal Chem ; 96(11): 4612-4622, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38462905

RESUMO

The iron nanozyme-based colorimetric method, which is widely applied for biosubstrate detection in in vitro diagnosis (IVD), faces some limitations. The optimal catalytic conditions of iron nanozymes necessitate a strong acidic environment, high temperature, and other restrictive factors; additionally, the colorimetric results are highly influenced by optical interferences. To address these challenges, iron nanozymes doped with various transition elements were efficiently prepared in this study, and notably, the manganese-modified one displayed a high catalytic activity owing to its electron transfer property. Furthermore, the introduction of lanthanide ions into the catalytic reactions, specifically the neodymium ion, significantly boosted the generation efficiency of hydroxyl radicals; importantly, this enhancement extended to a wide range of pH levels and temperatures, amplifying the detection signal. Moreover, the nanozyme's superparamagnetic characteristic was also employed to perform a logical optical and magnetic resonance dual-modality detection for substrates, effectively eliminating background optical interference and ensuring a reliable verification of the signal's authenticity. Based on this magnetic signal, the integration of natural glucose oxidase with the nanozyme resulted in a notable 61.5% increase in detection sensitivity, surpassing the capabilities of the traditional colorimetric approach. Consequently, the incorporation of lanthanide ions into the magnetic nanozyme enables the effective identification of physiological biomarkers through the dual-modality signal. This not only guarantees enhanced sensitivity but also demonstrates significant potential for future applications.


Assuntos
Elementos da Série dos Lantanídeos , Imageamento por Ressonância Magnética , Ferro , Espectroscopia de Ressonância Magnética , Íons/química , Colorimetria/métodos , Peróxido de Hidrogênio
14.
Anal Chim Acta ; 1299: 342453, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38499424

RESUMO

BACKGROUND: The development of wearable detection devices that can achieve noninvasive, on-site and real-time monitoring of sweat metabolites is of great demand and practical significance for point-of-care testing and healthcare monitoring. Monitoring uric acid (UA) content in sweat provides a simple and promising way to reduce the risk of gout and hyperuricemia. Traditional bioenzyme based UA assays suffer from high cost, poor stability, inconvenience for storage and easy deactivation of bioenzymes. Wearable microfluidic colorimetric detection device for sweat UA detection has not been reported. The development of novel wearable microfluidic colorimetric detection chip with no requirement of bioenzymes for sweat UA detection is of great importance for health care monitoring. RESULTS: Firstly, Co@MnO2 nanozyme with high oxidase-like activity was synthesized and characterized. Co@MnO2 can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) directly to generate blue-green colored ox-TMB. Green colored 2,2'-Azinobis-(3-ethylbenzthiazoline-6-sulphonate) radical (ABTS·+) was produced by the oxidation of ABTS by potassium persulfate. UA exhibits distinct quenching effect on Co@MnO2 catalyzed TMB colorimetric reaction system and ABTS·+ based colorimetric system, leading to obvious color fading of the two colorimetric systems. Then, a flexible microfluidic colorimetric detection chip for UA detection was fabricated by assembling Co@MnO2/TMB modified paper chips and ABTS·+ modified paper chips into a polydimethylsiloxane (PDMS) microfluidic chip. The fabricated microfluidic colorimetric detection chip exhibits good linear relationship for sweat UA detection. The linear range is from 20 to 200 µmol/L with detection limit as low as 6.6 µmol/L. Good results were obtained for the detection of UA in actual sweat from three volunteers. SIGNIFICANCE: This work provides two bio-enzyme free colorimetric detection systems for UA detection. Furthermore, a simple, low-cost and selective flexible wearable microfluidic colorimetric detection chip was fabricated for noninvasive and on-site detection of sweat UA, which holds great application potential for personal health monitoring and point-of-care testing.


Assuntos
Benzidinas , Benzotiazóis , Ácidos Sulfônicos , Suor , Ácido Úrico , Humanos , Microfluídica , Colorimetria/métodos , Compostos de Manganês , Óxidos , Catálise
15.
ACS Sens ; 9(3): 1321-1330, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38471126

RESUMO

A groundbreaking demonstration of the utilization of the metal-organic framework MIL-101(Fe) as an exceptionally perceptive visual label in colorimetric lateral flow assays (LFA) is described. This pioneering approach enables the precise identification of transglutaminase 2 (TGM2), a recognized biomarker for chronic kidney disease (CKD), in urine specimens, which offers a remarkably sensitive naked-eye detection mechanism. The surface of MIL-101(Fe) was modified with oxalyl chloride, adipoyl chloride, and poly(acrylic) acid (PAA); these not only improved the labeling material stability in a complex matrix but also achieved a systematic control in the detection limit of the TGM2 concentration using our LFA platform. The advanced LFA with the MIL-101(Fe)-PAA label can detect TGM2 concentrations down to 0.012, 0.009, and 0.010 nM in Tris-HCl buffer, urine, and desalted urine, respectively, which are approximately 55-fold lower than those for a conventional AuNP-based LFAs. Aside from rapid TGM2 detection (i.e., within 20 min), the performance of the MIL-101(Fe)-PAA-based LFA on reproducibility [coefficients of variation (CV) < 2.9%] and recovery (95.9-103.2%) along with storage stability within 25 days of observation (CV < 6.0%) shows an acceptable parameter range for quantitative analysis. A sophisticated sensing method grounded in machine learning principles was also developed, specifically aimed at precisely deducing the TGM2 concentration by analyzing immunoreaction sites. More importantly, our developed LFA offers potential for clinical measurement of TGM2 concentration in normal human urine and CKD patients' samples.


Assuntos
Aprendizado de Máquina , Estruturas Metalorgânicas , Proteína 2 Glutamina gama-Glutamiltransferase , Insuficiência Renal Crônica , Humanos , Colorimetria/métodos , Ferro , Proteína 2 Glutamina gama-Glutamiltransferase/urina , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/urina , Reprodutibilidade dos Testes
16.
Anal Chim Acta ; 1298: 342408, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38462333

RESUMO

BACKGROUND: In vitro screening strategies based on the inhibition of α-glucosidase (GAA) activity have been widely used for the discovery of potential antidiabetic drugs, but they still face some challenges, such as poor enzyme stability, non-reusability and narrow range of applicability. To overcome these limitations, an in vitro screening method based on GAA@GOx@Cu-MOF reactor was developed in our previous study. However, the method was still not satisfactory enough in terms of construction cost, pH stability, organic solvent resistance and reusability. Thence, there is still a great need for the development of in vitro screening methods with lower cost and wider applicability. RESULTS: A colorimetric sensing strategy based on GAA/(Au-Au/IrO2)@Cu(PABA) cascade catalytic reactor, which constructed through simultaneous encapsulating Au-Au/IrO2 nanozyme with glucose oxidase-mimicking and peroxidase-mimicking activities and GAA in Cu(PABA) carrier with peroxidase-mimicking activity, was innovatively developed for in vitro screening of GAA inhibitors in this work. It was found that the reactor not only exhibited excellent thermal stability, pH stability, organic solvent resistance, room temperature storage stability, and reusability, but also possessed cascade catalytic performance, with approximately 12.36-fold increased catalytic activity compared to the free system (GAA + Au-Au/IrO2). Moreover, the in vitro GAA inhibitors screening method based on this reactor demonstrated considerable anti-interference performance and detection sensitivity, with a detection limit of 4.79 nM for acarbose. Meanwhile, the method owned good reliability and accuracy, and has been successfully applied to the in vitro screening of oleanolic acid derivatives as potential GAA inhibitors. SIGNIFICANCE: This method not only more effectively solved the shortcomings of poor stability, narrow scope of application, and non-reusability of natural enzymes in the classical method compared with our previous work, but also broaden the application scope of Au-Au/IrO2 nanozyme with glucose oxidase and peroxidase mimicking activities, and Cu(PABA) carrier with peroxidase mimicking activity, which was expected to be a new generation candidate method for GAA inhibitor screening.


Assuntos
Ácido 4-Aminobenzoico , Inibidores de Glicosídeo Hidrolases , Inibidores de Glicosídeo Hidrolases/farmacologia , Glucose Oxidase , Reprodutibilidade dos Testes , Colorimetria/métodos , Peroxidases , Solventes , Peróxido de Hidrogênio
17.
Anal Methods ; 16(15): 2322-2329, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38533729

RESUMO

Cysteine is an important amino acid that is related to human health and food safety. How to effectively detect Cys in food has received widespread attention. Compared with other methods, fluorescent probes have the advantages of simple operation, high sensitivity, and good selectivity. Therefore, a selective fluorescence probe 2 for Cys in food was designed and synthesized. Probe 2 employed the acrylate group as a thiol-recognition site for Cys, which endowed probe 2 with better selectivity for Cys over Hcy and GSH. The recognition pathway underwent Michael addition, intramolecular cyclization, and concomitant release of the piperideine-based fluorophore, along with a chromogenic change from yellow to orange. This pathway was supported by 1H NMR analysis and DFT calculations. In addition, probe 2 displays a linear response to Cys concentrations (0-30 µM), low detection limit (0.89 µM), and large Stokes shift (125 nm). Overall, probe 2 showed great application potential for the quantitative determination of Cys in water, milk, cucumber, pear and tomato.


Assuntos
Cucumis sativus , Pyrus , Solanum lycopersicum , Humanos , Animais , Cisteína/análise , Cisteína/química , Cisteína/metabolismo , Cucumis sativus/metabolismo , Corantes Fluorescentes/química , Pyrus/metabolismo , Colorimetria/métodos , Água , Leite/química , Leite/metabolismo , Células HeLa
18.
ACS Appl Mater Interfaces ; 16(12): 14645-14660, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38478795

RESUMO

The greater advantages and wide applications of zero-dimensional nanodots inspire researchers to develop new materials. Therefore, novel borophene quantum dots (QDs) were prepared by a hydrothermal liquid exfoliation technique using water medium. The borophene QDs proved to be highly stable in water medium for more than 120 days. The synthesized borophene QDs revealed intrinsic peroxidase mimetic activity using two chromogenic substrates, 3,3',5,5'-tetramethylbenzidine (TMB) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid)diammonium salt (ABTS). The excellent intrinsic peroxidase activity toward TMB and ABTS substrates was executed using optimal reaction conditions (pH, borophene QDs' concentration, incubation time, and temperature). The formation of hydroxyl radicals in the presence of H2O2 upon TMB and ABTS oxidation played a significant role in the peroxidase reaction. The borophene QDs further proved to be successful for the colorimetric detection of antibiotics (oxytetracycline and tetracycline) using both TMB and ABTS peroxidase substrates. The limit of detection (LOD) for oxytetracycline and tetracycline was found to be 1.10 and 1.02 µM using TMB and 1.03 and 1.02 µM using ABTS chromogenic substrates, respectively. In addition, the fluorescence sensing of oxytetracycline and tetracycline over borophene QDs was also examined. The high fluorescence of borophene QDs (turn ON) was quenched (turn OFF) by oxytetracycline and tetracycline through the inner filter effect mechanism. The LOD of the fluorescence sensing of oxytetracycline and tetracycline was 1.14 and 1.08 µM, respectively. Interestingly, the borophene QDs could be used for the sensitive and selective colorimetric and fluorometric sensing of oxytetracycline and tetracycline after 120 days of storage. The synthesized borophene QDs with long-term stability and real sample analysis provide new insight as nanozymes with higher peroxidase mimetic and fluorescence performance and can be further exploited for medical diagnosis and environmental toxicants' detection.


Assuntos
Benzotiazóis , Oxitetraciclina , Pontos Quânticos , Ácidos Sulfônicos , Peroxidase , Compostos Cromogênicos , Peróxido de Hidrogênio/análise , Peroxidases , Antibacterianos/análise , Tetraciclina , Colorimetria/métodos , Água
19.
Anal Biochem ; 689: 115499, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38431141

RESUMO

MicroRNAs (miRNAs) are crucial biomarkers for the early detection and monitoring of disease progression of chronic obstructive pulmonary disease (COPD). Herein, we have devised a method for detecting miRNA using a combination of colorimetric and graphene oxide-based fluorescent techniques. The target miRNA in our design could precisely activate the trans-cleavage activity of the CRISPR-Cas13a system. The activated Cas13a enzyme cuts the "rUrU" section in the P1 probe, generating a nicking site to induce entropy-driven amplification (EDA). One of the available EDA products has the capability to unfold the hairpin probe, thereby initiating the catalytic hairpin assembly, exposing the G-quadruplex structure, facilitating the subsequent color response. The fuel strand labeled with Cy3 successfully established a double-stranded DNA structure with DNA3, and consequently the Cy3 would not be quenched by graphene oxide (GO). The implementation of the dual-mode technique in this method yields greater benefits in terms of improving the precision and consistency of the miRNA measurements. The developed method has the capability to fluorescently measure miRNA-21 levels down to a concentration of 5.8 fM. In addition, the analysis of miRNA targets from clinical samples using this method demonstrates its promising utility in the fields of biomedical research of COPD.


Assuntos
Técnicas Biossensoriais , Grafite , MicroRNAs , Doença Pulmonar Obstrutiva Crônica , Humanos , MicroRNAs/genética , Colorimetria/métodos , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas , Entropia , Técnicas de Amplificação de Ácido Nucleico/métodos , Corantes
20.
Anal Methods ; 16(14): 2044-2050, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38501322

RESUMO

The preparation of cobalt-based nanozymes with high oxidase-like activity still needs more efforts. In this paper, we report the synthesis of a CoO/Co-tryptophan-functional graphene quantum dot hybrid (CoO/Co-Try-GQD). Firstly, cobalt ions coordinate with the indole nitrogen on Try-GQD to form a complex, followed by thermal reduction and oxidation. The resulting hybrid presents a three-dimensional network structure, and CoO/Co nanoparticles are uniformly dispersed on the graphene sheet with an average size of 10 ± 0.24 nm. This unique structure improved the oxidase-like activity of the hybrid, enabling it to catalyze the oxidation of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to rapidly produce deep blue ox-TMB with a strong absorbance at 652 nm (A652). A colorimetric method was developed for the highly sensitive determination of L-cysteine (L-cys) based on the inhibition of the hybrid's oxidase-like activity and low A652 caused by the binding of L-cys with Co atoms on CoO/Co via the Co-S bond. The A652 linearly decreased with increasing L-cys concentration in the range of 0.05-2 µM, and the detection limit was 0.032 µM. Further, the established method has been successfully applied to the determination of L-cys in milk.


Assuntos
Benzidinas , Grafite , Pontos Quânticos , Grafite/química , Cisteína/metabolismo , Pontos Quânticos/química , Colorimetria/métodos , Oxirredutases/química , Oxirredutases/metabolismo , Cobalto/química , Estresse Oxidativo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...